Technical specifications for low-dose computed tomography for lung cancer screening:expert consensus
Kang Chengxin, Fu Binjie, Lü Fajin, Li Zhenli, Yu Jianming, Lei Ziqiao, Fu haihong, Ma Xinwu, Zhao Yanming, Liu Jie, Zhou Gaofeng, Niu Yantao, Kang Zhuang, Bao Yunfeng, Lu Qing, Yin Jiandong
Technical specifications for low-dose computed tomography for lung cancer screening:expert consensus
Objective To propose a standardized low-dose computed tomography(LDCT) protocol for lung cancer screening,and to provide guidance for rational and standardized application of LDCT for the detection and diagnosis of pulmonary nodules. Methods The experts from the Chinese Society of Imaging Technology participated in the formulation of technical specifications for LDCT lung cancer screening. This consensus was based on recent advances on LDCT lung cancer screening at home and abroad and the epidemiology of lung cancer in China,covering the applicable scope,scanning parameters,range of radiation dose,and image quality control standards. Results This consensus specifies that the effective dose of LDCT for lung cancer screening should be less than or equal to 1 mSv. According to the body mass index(BMI) of examinees,for small BMI(<18.5 kg/m2),medium BMI(18.5-24.9 kg/m2),and large BMI(≥25 kg/m2),the recommended tube voltages are ≤100 kV,100~120 kV,and 120 kV,respectively,and the recommended tube currents are 20 mAs,30 mAs,and 30 mAs,respectively. The reconstruction kernel is recommended to be standard or medium. Using the vertebral spinous processes as landmarks,the scanning range should be from the upper edge of the T1 spinous process to the lower edge of the T12 spinous process for examinees with BMI ≥21 kg/m2 and from the upper edge of the T1 spinous process to the lower edge of the L1 spinous process for those with BMI <21 kg/m2. Scanning should be performed using the breath-hold technique at the end of deep inspiration. The recommended image post-processing methods include multi-planar reconstruction,10-mm maximum intensity projection,3 mm minimum intensity projection,and multi-slice volume reconstruction. Conclusion This expert consensus on the whole process of LDCT for lung cancer screening can facilitate homogeneous scanning across different medical institutions,improving the mutual recognition of imaging results.
lung cancer screening / low radiation dose / CT examination specifications
1 |
|
2 |
|
3 |
|
4 |
National Lung Screening Trial Research Team,
|
5 |
中国肺癌早诊早治专家组,中国西部肺癌研究协作中心. 中国肺癌低剂量CT筛查指南(2023年版)[J]. 中国肺癌杂志,2023,26(1):1-9.
China national lung cancer screening guideline with low-dose computed tomography (2023 version)[J]. Chin J Lung Cancer,2023,26(1):1-9.
|
6 |
The American Association of Physicists in Medicine. Lung Cancer Screening CT Protocols Version 6.0[EB/OL]. [2024-07-04].
|
7 |
National Lung Screening Trial Research Team,
|
8 |
|
9 |
US Preventive Services Task Force,
|
10 |
周清华,范亚光,王 颖,等. 中国肺癌低剂量螺旋CT筛查指南(2018年版)[J]. 中国肺癌杂志,2018,21(2):67-75.
|
11 |
|
12 |
|
13 |
梁张瑞,刘香仱,吕发金. 基于正位定位像精准制定胸部低剂量CT扫描范围的优势及方法初步研究[J]. 川北医学院学报,2021,36(9):1146-1149.
|
14 |
The American College of Radiology. ACR-ASNR-SPR practice parameter for the performance of computed tomography(CT) of the extracranial head and neck[EB/OL]. [2024-07-04].
|
15 |
|
16 |
|
17 |
|
/
〈 |
|
〉 |